White Georgia

White Georgia - Marble

Description

A timeless classic that has established itself among many generations past and present, this white marble bearing the name of its home in the hills of Georgia is of the greatest purity and quality. Sparkling calcite crystals create dazzling reflections, while very faint and subtle veins of diffused grey cut across the surface, making it a strong choice for refined tastes.

Applications

Tiles, slabs, blocks, mosaics, architectural stone, curbs & pavers, other cut-to-size projects

Quarry Location

Marble Hill , GA, US

Sample Order

Desired finish :

Quantity :



Finishes



ASTM ImperialMetric
Absorption by weightASTM C970.08%0,08%
Compressive strengthASTM C1709 883Psi68,14Mpa
DensityASTM C97170.4lb/ft32 730kg/m3
Modulus of ruptureASTM C991 467Psi10,12Mpa

* Polycor has made reasonable efforts to ensure the accuracy of the information contained in this Web site. Said information is however solely provided for reference purposes and Polycor makes no representation or warranty of any nature with respect to the exactness or completeness of this information. Polycor shall hence, under no circumstance, be held responsible for any damage or incident incurred as a result, either direct or indirect, of the use of the information herein provided

Category Name Credits Requirements Compatibility
Materials & ResourcesResource Reuse: 5% & 10% (1-2 pts)3.1 & 3.2 Use salvaged, refurbished or reused materials, products and furnishings for 5% to 10% of the total cost of building materialManufacturer regularly sources product to refinish and refurbish from existing demolition projects such as historic buildings. Contact Manufacturer for specific information.
Materials & ResourcesRegional Materials: 10% & 20% (Extracted and Manufactured Regionally) (1-2 pts)5.1 & 5.210% to 20% of all project materials (by weight) to be extracted and manufactured within 800km - 2400km via truck or rail respectively.Due to the location of our quarries and installation, our granite and marble are considered local products mainly in the North East of the United States and the East Coast in general. See our location map.
Materials & ResourcesDurable Building (1 pt)8.0Develop and implement a Durable Building Plan. This includes choosing durable materials and components which reduce the need for new materials and the environmental costs of resource extraction, production processes and waste disposal.If product is well maintained: Low traffic interior = 150+ years, High traffic interior = 40+ years. Low traffic exterior = 75+ years. Well maintained countertops can last 150+ years. Results may vary.
Sustainable SitesHeat Island Effect: Non-Roof (1 pt)7.1Provide shade (within 5 years) and/or use light-coloured / high-albedo materials (reflectance of at least 0.3) and/or open grid pavement for at least 30% of the site’s non-roof impervious surfaces, including parking lots, walkways, plazas, etc.;This product is light-coloured and can be used as exterior walkways. *Emissivity testing by ASTM TBA.
Energy & AtmosphereMinimum and Optimal Energy Performance (1-10 pts)Prerequisite 2 & Credit 1Design the building to surpass either CBIP or ASHRAE energy performance standards for a building.This product can aid in achieving this credit by adding thermal mass to the building as cladding or other large installation application. *Dependent on Architect.
Materials & ResourcesConstruction Waste Management: 50% & 75% (1-2 pts)2.1 & 2.2Divert 50% to 75% project construction waste from landfillManufacturer does not have a take back program, however, due to the value of the product it is rarely sent to the landfill. *Dependent on contractor.
Indoor Environmental QualityConstruction IAQ management plan: During Construction (1 pt)3.1“Materials that are potentially noxious should be identified by the project architect, and control measures specified, as described in the SMACNA guidelines.” (CaGBC recommendation but NOT part of the required LEED submittals).This product may off-gas a very small amount of Radon. *This is not part of LEED required submittals.* Dependent on architect.
Indoor Environmental QualityLow-Emitting Materials: Adhesives and Sealants (1pt)4.1The VOC content of adhesives, sealants and sealant primers used must be less than the VOC content limits of the State of California’s South Coast Air Quality Management District (SCAQMD) Rule #1168, October 2003.The manufacturer does not have a specific recommended adhesive or sealant for this product. However, in order to meet the requirements of this credit the installer should use third party certified LOW VOC adhesives & sealants. *Dependent on installer.
  • Henry Ford Museum
    MI, US

    New York Stock Exchange
    NY, US

    First Virginia Bank
    VA, US

    Emory School of Medecine
    GA, US


SEE MORE PROJECTS

State

Marble Hill , GA, US

Annual Production

500 m3 (20,000 cu.ft) and more

Properties

The same colors as over 100 years ago are extracted today from our 400 acres property.

Reserve

More than a century.

Status

Intermittent operation to follow market demand.


There is no range with this color

Related products